Laboratory EMC and Safety Test
The EMC and Safety Test Laboratory performs compliance tests, based on EU low voltage (LVD) and electromagnetic compatibility (EMC) directives and CE marking requirements on products designed and manufactured by INTRACOM TELECOM as well as other OEMs.
According to the new RTTE directive, the laboratory is fully equipped to perform compliance tests on telecommunication and radio-communication terminal equipment. An anechoic chamber for acoustic measurements is part of the Laboratory's infrastructure.
The laboratory also offers consulting services during product development
Facilities Available
- 6.5m x 5m x 2.5m SHIELDED ROOM
for performing immunity measurements
- 2.5m x 3.5m x 2.5m CONTROL ROOM
- 7m x 3,5m x 3m RF-ANECHOIC CHAMBER
lined with:
- TDK's ferrite tiles for performing radiated immunity tests and emissions measurements
- TDK IP-045 Cone Absorbers
for upgraded performances up to 18GHz
- 3.0m x 2.5m x 2.5m ACOUSTIC
ANECHOIC chamber performing CTR Acoustic measurements
for Telecommunication Terminal Equipment.
Tests and Services
Tests and Services for commercial and
telecommunication products include:
- Radio and Telecom Tests:
R & TTE Directive 1999/5/EC
- Product Safety Tests :
Low Voltage Directive (LVD) 2006/95/EC
- Electromagnetic Compatibility Tests:
EMC Directive 2004/108/EC.
a) Emissions Tests:
- Conducted Emissions
- Radiated Emission
- Harmonics and Voltage Fluctuations
b) Immunity Tests:
- Electrostatic Discharges (ESD)
- Fast Transient Burst
- Radiated RF Immunity
- Conducted RF Immunity
- Resistibility to surges and
overvoltages, Voltage Variations, Dips and Short Interruptions
Services for EMC consultancy include:
- EMC Design Consultancy
- Advice on routes to EMC Compliance
- Advice on applicable standards.
- Computational electromagnetic modeling by EMI simulation
software (PCB layout stage routing).